•   info@chestspecialistallahabad.com
  •   Call Us: +91 9792456999

FOT Test in prayagraj

FREQUENCY OSCILLATION TESTING (FOT)
This is a modern and relatively unique method of looking at airway narrowing. It capitalizes on the fact that different sound wave frequencies (low pitch to slightly higher pitch sounds) travel different distances along the airway. The lowest of these travels the furthest. When this test is carried out multiple low variable sound wave frequencies are sent down the airways and the time to travel down and reflect back are measured. This then provides information on what is happening along the full length of the airway.

This test is carried out at rest with gentle breathing and so the airways are not subject to the physical forces that occur when individuals undertake a forced maneuver (breathing out as fast as possible).

 

Normal population data has been most extensively collected for Very Low Pitch sound (5Hertz) and for slightly higher pitch sounds (20 Hertz). Below 20 hertz is not audible to humans. As such, we use the results from these two frequencies (R5 & R20) to provide information on the resistance to air flow for the full length of the airway (R5) and for the first third of the airways, ie the larger airways, (R20). The difference of these two readings also inform us about the lungs’ smaller airways which are hard to measure by other means. 

 

FOT test

The additional value of this test is that it does not require any special effort from the patient. The patient is simply asked to hold their cheeks and to breathe normally for a few minutes. If it is your first ever test you may be asked to repeat the test after having taken an inhalation of a ‘Ventolin’ equivalent puffer. It is much simpler than other tests (eg Spirometry) that are used more commonly in assessing air flow. Combining the information from spirometry and FOT provides a much more powerful assessment of your airway pathology.

Tobacco smoke exposure is the second leading risk factor for early death and disability and has been directly responsible for more than 5 million deaths every year since 1990. The deterioration in pulmonary function seen in chronic obstructive pulmonary disease (COPD) is related to smoke inhalation by the patient comprising duration and number of smoking pack years as well as exposure to other sources of smoke pollution such as biomass fuel. Dysfunction of the peripheral airways, lung parenchyma and microvasculature are common in smokers.It is believed that small airways (<2 mm) are the initial sites of inflammation and destruction in COPD and represent the silent zone of lung disease with earlier damage occurring without leading to observable airflow obstruction or symptoms. The clinical consequences of these changes remained unexplored, potentially due to the lack of sensitive diagnostic tests to measure small airway function and the capacity of the human respiratory system to apparently function normally until the majority of airways become abnormal.

 

We have facility of FOT Test Lab at: 

Haridaya Superspeciality Centre
Dr. Ahish Tandon
16/28, Stanley Road, Civil Lines,
Near Police Line Helicopter Landing Site,
Allahabad, Uttar Pradesh 211001,India
+91 9792456999, +91 9336281819, +91 8004915141
info@chestspecialistallahabad.com

For more details, please contact Haridaya Superspecality Centre or contact us at 9792456999 / 9336281819 / 8004915141 or email us at info@chestspecialistallahabad.com. We have extensive experience in offering wide range of Chest Treatments.